4.2.6 Query Commands
4.2.6.1 Read Vendor Information
4.2.6.2 Read Model Information
4.2.6.3 Read Product ID
Purpose: To read the camera vendor’s name.
Type: This is a read only command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x01 1 16 -
Response: Cmd-ID R/W-Flag Data Length Data
0x01 0 16 16 Bytes
Data Format: Zero terminated string if less than 16 bytes are needed for the vendor
information. Unterminated string if all 16 bytes are needed.
Purpose: To read the camera’s model number.
Type: This is a read only command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x02 1 16 -
Response: Cmd-ID R/W-Flag Data Length Data
0x02 0 16 16 Bytes
Data Format: Zero terminated string if less than 16 bytes are needed for the model
information. Unterminated string if all 16 bytes are needed.
Purpose: To read the camera’s product ID number.
Type: This is a read only command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x03 1 16 -
Response: Cmd-ID R/W-Flag Data Length Data
0x03 0 16 16 Bytes
Data Format: Zero terminated string if less than 16 bytes are needed for the product ID
information. Unterminated string if all 16 bytes are needed.