Configuring the Camera
Basler A500
k 4-23
PRELIMINARY
4.2.5 Test Image Command
Purpose: To enable or disable a test image, and to select a test image. See section 3.11 for an
explanation of the available test images.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0xA1 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0xA1 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0xA1 0 1 1 Byte
Response: None
Data Format: Byte 1 An ID that specifies the test image (see the table below).
ID Test Image
0x00 Image from sensor (standard mode)
0x01 Gray Gradient Test Image
0x03 Running Line Test Image
0x04 White Screen Test Image