Configuring the Camera
4-14 BASLER A600
f
DRAFT
Register Name: Gain Inquiry
Offset from Base Address: 0x520
Field Bit Description A601f / A601fc
A602f / A602fc
Value
Presence Inq
0 Gain control feature is present 1
Abs Control Inq 1 Gain can be set with an absolute value 0
--- 2 Reserved ---
One Push Inq 3 One push auto mode is present 0
Read Out Inq 4 The gain value can be read 1
On/Off Inq 5 Gain control can be switched on/off 0
Auto Inq 6 A gain auto control mode is present 0
Manual Inq 7 The gain value can be set manually 1
Min Value 8 ... 19 Minimum value for gain 000
Max Value 20 ... 31 Maximum value for gain 255