Configuring the Camera
Basler L304kc 4-31
Draft
Mirror Image Mode CSR
Register Base Address: 0x3500
Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read only
Description: The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
Field Name: Mode Offset: 0x0001 Size: 1 Byte Type: Read / Write
Description: Writing an integer value to this field sets the mirror image mode:
0x00 = Mirror image disabled
0x01 = Mirror image enabled
See Section 3.9 for more information about the mirror image feature.