AW00104701000 Physical Interface
Basler scout light GigE 65
Voltage Levels When a PLC Power and I/O Cable is Used
The following voltage requirements apply to the input of the PLC power and I/O cable. The PLC
power and I/O cable will adjust the voltages to the levels required at the camera’s I/O input (see
Table 4).
Voltage Significance
+0 to +24 VDC Recommended operating voltage.
+0 to +8.4 VDC The voltage indicates a logical 0.
> +8.4 to +10.4 VDC Region where the transition threshold occurs; the logical state is not defined in this
region.
> +10.4 VDC The voltage indicates a logical 1.
+30.0 VDC Absolute maximum; the camera may be damaged when the absolute maximum is
exceeded.
Table 7: Voltage Requirements for the I/O Input When Using a PLC Power and I/O Cable