Configuring the Camera
BASLER A620
f 4-39
DRAFT
Register Name: Strobe 1 Control
Offset from Base Address: 0x204
Field Bit Description
Same definitions and values as Strobe 0 Control.
Register Name: Strobe 2 Control
Offset from Base Address: 0x208
Field Bit Description
Same definitions and values as Strobe 0 Control.
Register Name: Strobe 3 Control
Offset from Base Address: 0x20C
Field Bit Description
Same definitions and values as Strobe 0 Control.
L
If a strobe signal is on, the signal will only be present on the associated output port
if the output port is configured for “strobe.” For example, if the Strobe 0 signal is
on, the signal will only be present on physical output port 0 if the port is configured
for “strobe”. If the Strobe 1 signal is on, the signal will only be present on physical
output port 1 if the port is configured for “strobe”. Etc.
See Section 6.7.10 for more information about configuring the output ports.