Basler A620f Manual de usuario Pagina 102

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 101
Image Data Formats & Structures
5-8 BASLER A620
f
DRAFT
5.4.3 Data Structure for a Y (Mono 16) Component
The data output for a Y (mono 16) component is 16 bit data of the “unsigned short (little endian)”
type. The range of data values for a Y mono component and the corresponding indicated signal
levels are shown below.
This Data Value
(Hexadecimal)
Indicates This Signal Level
(Decimal)
0x03FF 1023
0x03FE 1022
••
••
••
0x0001 1
0x0000 0
L
Normally, the data values for a 16 bit component would range from 0x0000 to 0xFFFF.
However, when an A600f camera is set for 16 bit output, only 10 bits are effective.
Therefore, the highest data value you will see is 0x03FF indicating a signal level of
1023.
Vista de pagina 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 143 144

Comentarios a estos manuales

Sin comentarios