Acquisition Control AW00118501000
54 Basler racer Camera Link
If the camera is set for rising edge triggering, the exposure time starts when the ExLSTrig signal
rises. If the camera is set for falling edge triggering, the exposure time starts when the ExLSTrig
signal falls. Fig. 11 illustrates timed exposure with the camera set for rising edge triggering.
Note that if you attempt to trigger a new exposure start while the previous exposure is still in
progress (overtriggering), the trigger signal will be ignored. This situation is illustrated in Fig. 12 for
rising edge triggering.
ExLSTrig Signal Period
ExLSTrig Signal
Fig. 11: Timed Exposure with Rising Edge Triggering
Exposure
(duration determined by the
exposure time parameter or
register setting)
This rise in the trigger signal will be
ignored due to overtriggering
ExLSTrig Signal
Fig. 12: Overtriggering with Timed Exposure
Exposure
(duration determined by the
exposure time parameter or
register setting)