Physical Interface AW00098504000
42 Basler ace Camera Link
Figure 14 shows a typical circuit you can use to monitor the output line with a voltage signal.
1
2
3
4
4-Pin
Receptacle
Camera
390
4.7k
Gnd
GPIO_Out
U
I/O_Gnd
TLP281
Q1
BC846W
Gnd
120
GPIO_Out_Ctrl
(from FPGA)
GPIO_Gnd
Fig. 13: Schematic with GPIO Set as an Output
1
2
3
4
4-Pin
Receptacle
Camera
390
4.7k
Gnd
GPIO_Out
U
I/O_Gnd
TLP281
Q1
BC846W
Gnd
120
GPIO_Out_Ctrl
(from FPGA)
GPIO_Gnd
Your
Gnd
Your
Gnd
+3.3 to +24
VDC
1k
Voltage
Output
Signal
to You
Fig. 14: Typical Voltage Output Circuit